0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HCA 10000

HCA 10000

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

    TE CONNECTIVITY - HCA 10000 - HERMETICALLY SEALED AC LVDT, 3KOHM

  • 数据手册
  • 价格&库存
HCA 10000 数据手册
HCA & HCA-RA SERIES Hermetically Sealed AC LVDT SPECIFICATIONS          FEATURES  All-welded stainless steel       construction Glass sealed, MS type connector (MIL-C-5015) Shock and vibration tolerant Captive core eases installation (optional) High temperature version available (200ºC) Calibration certificate supplied with each unit Right angle (HCA-RA) version available APPLICATIONS       Harsh industrial environments Submersible (with appropriate connector) Pressure vessels Corrosive liquid and vapor areas (check materials) Mild radiation areas Turbine valve SENSOR SOLUTIONS /// HCA & HCA-RA Series Rev. 10 Hermetically sealed, all welded Stainless steel housing MS type connector, glass sealed Axial or radial electrical connection IEC IP68 rating to 1,000 PSI [70 bars] Stroke ranges from ± 0.05 to ±10 inches AC operation from 400Hz to 10kHz Double magnetic shielding Through bore design (HCA-RA version) The HCA and HCA-RA Series hermetically sealed LVDTs provide premium performance in harsh industrial environments. Impervious to dirt, water, steam, and corrosive liquids/vapors compatible with its materials, the HCA/HCA-RA all-welded stainless steel construction withstands external pressures up to 1,000 PSI [70 bars]. Double magnetic shielding offers excellent protection from external electromagnetic fields. The HCA/HCA-RA Series can be configured with a number of standard options. A high temperature operation (200ºC) model, HCA-T is also available. The HCA/HCA-RA is compatible with the full line of Measurement Specialties LVDT signal conditioners. The HCA-RA version adds the convenience of a radial connector termination. This feature decreases the required installation space, while also allowing debris to harmlessly pass through the ‘open-ended’ bore. Like in most of our LVDTs, the HCA/HCA-RA windings are vacuum impregnated with a specially formulated, high temperature, flexible resin, and the coil assembly is potted inside its housing with a two-component epoxy. This provides excellent protection against hostile environments such as high vibration and shock. Captive core option: The HCA/HCA-RA features an optional captive core design that greatly simplifies installation. The core rod and bearing assembly includes a Bronze bearing on the front end for self-alignment, while a PTFE sleeve allows low-friction travel through the stainless steel boreliner (spool tube). Also see our other hermetically sealed LVDT models with built-in signal conditioning: HCD (DC voltage), HCT (4-20mA, 2-wire loop) and HC-485 (RS-485 Digital Series). 07/2017 Page 1 HCA & HCA-RA SERIES Hermetically Sealed AC LVDT PERFORMANCE SPECIFICATIONS ELECTRICAL SPECIFICATIONS Parameter HCA HCA-RA 050 HCA HCA-RA 125 HCA HCA-RA 250 HCA HCA-RA 500 HCA HCA-RA 1000 HCA HCA-RA 2000 HCA HCA-RA 3000 HCA HCA-RA 4000 HCA HCA -RA 5000 HCA HCA-RA 10000 ±0.050 [±1.27] 4.2 [165] ±0.125 [±3.17] 2.4 [94.5] ±0.25 [±6.35] 1.6 [63.0] ±0.5 [±12.7] 1.1 [43.3] ±1 [±25.4] 0.84 [33.1] ±2 [±50.8] 0.32 [12.6] ±3 [±76.2] 0.20 [7.9] ±4 [±101.6] 0.18 [4.6] ±5 [±127] 0.16 [6.3] ±10 [±254] 0.13 [5.1] 210 300 400 550 840 640 600 720 800 1,300 +6° +5° +5° +2° +1° -1° +1° +3° -5° -6° 430Ω 1710Ω 800Ω 900Ω 900Ω 525Ω 930Ω 1000Ω 1200Ω 930Ω 950Ω 1820Ω 940Ω 1150Ω 2100Ω 535Ω 1040Ω 580Ω 1640Ω 3000Ω 0.25 0.25 0.25 0.25 ±% of FR 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.30 0.30 0.35 0 .50 / 0 .80 0.90 (**) 0.50 0.50 0.50 0.55 (**) 0 .55 (**) 1.00 (**) / / / Stroke range Sensitivity V/V/inch mV/V/mm Output at stroke ends, mV/V (*) Phase shift Input impedance (PRIMARY) Output impedance (SECONDARY) Non-linearity @100% stroke (maximum) @125% stroke @150% stroke Input voltage Input frequency Test frequency Null voltage 0 .40 (**) 0 .70 (**) 3 VRMS sine wave 400Hz to 10kHz 2.5kHz 0.5% of FRO, maximum ENVIRONMENTAL SPECIFICATIONS & MATERIALS Operating temperature Shock survival Vibration tolerance Housing material Electrical connector IEC 60529 rating -65°F to +300°F [-55°C to 150°C] 1,000 g (11ms half-sine) 20 g up to 2kHz AISI 400 Series stainless steel 6-pin MS type connector (MIL-C-5015) IP68 to 1,000 PSI [70 bars] with use of proper mating connector plug Notes All values are nominal unless otherwise noted Electrical specifications are for the test frequency indicated in the table Dimensions are in inch [mm] unless otherwise noted FR: Full Range is the stroke range, end to end; FR=2xS for ±S stroke range FRO (Full Range Output): Algebraic difference in outputs measured at the ends of the range (*) Unit for output at stroke ends is millivolt per volt of excitation (input voltage) (**) Requires special reduced core length SENSOR SOLUTIONS /// HCA & HCA-RA Series Rev. 10 07/2017 Page 2 HCA & HCA-RA SERIES Hermetically Sealed AC LVDT MECHANICAL SPECIFICATIONS – NON CAPTIVE CORE (STANDARD) Parameter HCA HCA-RA 050 HCA HCA-RA 125 HCA HCA-RA 250 HCA HCA-RA 500 HCA HCA-RA 1000 HCA HCA-RA 2000 HCA HCA-RA 3000 HCA HCA-RA 4000 HCA HCA-RA 5000 HCA HCA-RA 10000 Body length “A” 1.66 [42.2] 0.59 [15.0] 1.07 [27.2] 0.55 [14.0] 1.20 [34] 2.26 [64] 0.07 [2] 2.50 [63.5] 1.10 [27.9] 1.91 [48.5] 0.96 [24.4] 1.73 [49] 2.79 [79] 0.11 [3] 3.36 [85.3] 1.80 [45.7] 2.77 [70.4] 1.39 [35.3] 2.22 [63] 3.28 [93] 0.14 [4] 5.05 [128.3] 3.00 [76.2] 7.29 [185.2] 3.80 [96.5] 6.72 [170.7] 3.32 [84.3] 5.22 [148] 6.28 [178] 0.39 [11] 10.68 [271.3] 5.30 [134.6] 10.20 [259.1] 15.76 [400.3] 6.20 [157.5] 15.17 [385.3] 7.59 [192.8] 8.33 [236] 9.38 [266] 0.60 [17] 16.17 [410.7] 19.70 [500.4] 6.20 [157.5] 19.12 [485.6] 9.56 [242.8] 10.31 [292] 11.35 [322] 0.60 [17] 33.82 [859.0] 12.00 [304.8] 33.23 [844.0] 16.61 [421.9] 18.57 [526] 19.61 [556] 0.85 [24] Core length “B” Bore depth “C” HCA only Core center at null “P” HCA body weight oz [g] HCA-RA body weight, oz [g] Core weight oz [g] 4.46 [113.3] 2.23 [56.6] 2.93 [83] 3.98 [113] 0.28 [8] 4.91 [124.7] 5.65 [160] 6.70 [190] 0.46 [13] 6.20 [157.5] 7.87 [199.9] 8.50 [241] 9.60 [272] 0.60 [17] Dimensions are in inch [mm] SENSOR SOLUTIONS /// HCA & HCA-RA Series Rev. 10 07/2017 Page 3 HCA & HCA-RA SERIES Hermetically Sealed AC LVDT MECHANICAL SPECIFICATIONS – CAPTIVE CORE OPTION Parameter HCA/HCARA 050 HCA/HCARA 125 HCA/HCARA 250 HCA/HCARA 500 HCA/HCA-RA 1000 HCA/HCARA 2000 HCA/HCARA 3000 Body length “A” 2.00 [50.8] 0.89 [22.6] 3.70 [94.0] 1.98 [56] 2.84 [72.1] 1.30 [33.0] 4.28 [108.7] 2.61[74] 3.70 [94.0] 1.73 [43.9] 4.75 [120.6] 3.14 [89] 5.39 [136.9] 2.57 [65.3] 6.04 [153.4] 4.06 [115] 7.63 [193.8] 3.66 [93.0] 7.90 [200.7] 6.63 [188] 11.02 [279.9] 5.39 [136.9] 10.52 [267.2] 7.37 [209] 16.10 [408.9] 7.93 [201.4] 15.27 [387.9] 10.62 [301] Core center at null “P” Core rod position at null “R” Weight, oz [grams] Dimensions are in inch [mm] WIRING INFORMATION A through F: Connector pin assignments Connect B to C for differential output SENSOR SOLUTIONS /// HCA & HCA-RA Series Rev. 10 07/2017 Page 4 HCA & HCA-RA SERIES Hermetically Sealed AC LVDT ORDERING INFORMATION Description HCA Model Part Number Description HCA-RA Model Part Number ±0.050 inch LVDT ±0.125 inch LVDT ±0.25 inch LVDT ±0.5 inch LVDT ±1 inch LVDT ±2 inch LVDT ±3 inch LVDT ±4 inch LVDT ±5 inch LVDT ±10 inch LVDT HCA 050 HCA 125 HCA 250 HCA 500 HCA 1000 HCA 2000 HCA 3000 HCA 4000 HCA 5000 HCA 10000 02560413-000 02560414-000 02560415-000 02560416-000 02560417-000 02560418-000 02560419-000 72560000-000 02560420-000 02560421-000 ±0.050 inch LVDT ±0.125 inch LVDT ±0.25 inch LVDT ±0.5 inch LVDT ±1 inch LVDT ±2 inch LVDT ±3 inch LVDT ±4 inch LVDT ±5 inch LVDT ±10 inch LVDT HCA-RA 050 HCA-RA 125 HCA-RA 250 HCA-RA 500 HCA-RA 1000 HCA-RA 2000 HCA-RA 3000 HCA-RA 4000 HCA-RA 5000 HCA-RA 10000 02560413-500 02560414-500 02560415-500 02560416-500 02560417-500 02560418-500 02560419-500 72560000-500 02560420-500 02560421-500 OPTIONS Description 5.0 kHz calibration 10 kHz calibration Metric threaded core (Non-captive) or connecting rod (Captive core) Guided core Small-diameter/low-mass core (consult factory for mass and dimensions) Captive core Comments Part Number HCA/HCA-RA 050 through HCA/HCA-RA 500 only All Available on non-captive core models only HCA/HCA-RA 050 through HCA-RA 3000 only XXXXXXXX-002 XXXXXXXX-003 XXXXXXXX-006 XXXXXXXX-010 XXXXXXXX-020 XXXXXXXX-200 Note: Add multiple option dash numbers together to determine proper ordering suffix Example: HCA-RA 1000, ±1 inch, right angle connector model, with captive core and 5 kHz calibration, P/N 0256417-702 ACCESSORIES FOR HCA AND HCA-RA Description Core connecting rod, 6 inches long, 4-40 threads Core connecting rod, 12 inches long, 4-40 threads Core connecting rod, 24 inches long, 4-40 threads Core connecting rod, 36 inches long, 4-40 threads Core connecting rod, 6 inches long, M3x0.5 metric threads Core connecting rod, 12 inches long, M3x0.5 metric threads Mounting block Mating connector kit Interconnect cable for LVM-110 and LiM 4-20 Signal Conditioners (1) Interconnect cable for IEM-422 Signal Conditioner (1) Interconnect cable for ATA-2001 Signal Conditioner (1) Interconnect cable for MP-2000 Series Set-Point Controller (1) Interconnect cable for LDM/PML-1000 Signal Conditioners, 200°C (1) Comments Part Number 05282946-006 05282946-012 05282946-024 05282946-036 05282977-006 05282977-012 04560950-000 PT06A-10-6S(SR) 62101011-000 HCA/HCA-RA to Stripped/Tinned 04290417-000 HCA/HCA-RA to PTO6A-10-6P 04290133-000 HCA/HCA-RA to DB-9P 04290457-000 HCA/HCA-RA to 05BL5M 04290560-000 HCA/HCA-RA to Stripped/Tinned 04290595-000 (1) All cables are shielded, 10 foot long, and rated 80°C [176°F] operating unless otherwise noted. Consult factory for other lengths. SENSOR SOLUTIONS /// HCA & HCA-RA Series Rev. 10 07/2017 Page 5 HCA & HCA-RA SERIES Hermetically Sealed AC LVDT NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity company Tel: 800-522-6752 Email: customercare.frmt@te.com EUROPE ASIA Measurement Specialties (Europe), Ltd., a TE Connectivity Company Tel: 800-440-5100 Email: customercare.bevx@te.com Measurement Specialties (China) Ltd., a TE Connectivity company Tel: 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS /// HCA & HCA-RA Series Rev. 10 07/2017 Page 6
HCA 10000 价格&库存

很抱歉,暂时无法提供与“HCA 10000”相匹配的价格&库存,您可以联系我们找货

免费人工找货